DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1449UDS1-BD (UDS1 Interface Circuit Pack)
10
NPE Connection Audit Test (#50)
The system sends a message to the on-board microprocessor to update the
network connectivity translation for the SCOTCH-NPE chip on the circuit pack.
1. D = Destructive; ND = Nondestructive
Far CSU Loopback Test
(#1213)
XD
One-Way Span Test
(#1214)
XD
Inject Single Bit Error
(#1215)
XD
End Loopback/Span Test
(#1216)
XD
Table 10-490. TEST #50 NPE Connection Audit Test
Error
Code
Test
Result Description/ Recommendation
None
2100
ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1019 ABORT The test aborted because a test was already running on the port.
1. Retry the command at 1 minute intervals for a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort/fail, escalate the problem.
PASS The circuit pack’s SCOTCH-NPE chip have been updated with its
translation.
Continued on next page
Table 10-489. System Technician-Demanded Tests: Descriptions and Error Codes — Continued
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Reset Board
Sequence
test ds1-loop
Command D/ND
1
Continued on next page