Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-81ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)
10
1000 ABORT System resources required to run this test were not available. The port may
be busy with a valid call.
Use the display port PCSSpp to determine the station’s extension. Enter
status station extension to determine the service state of the port. If the
port is in use, it will be unavailable for certain tests. Wait until the port is idle
before retesting.
1. If the port is idle, retry the command at 1-minute intervals up to 5 times.
2. Check for phone left off-hook or for wiring problems.
1004 ABORT System resources required to run this test are not available. The port may
be busy with a valid call. Use the display port PCSSpp command to
determine the station extension. Use the status station command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 8, "Maintenance Commands and
Trouble-Clearing Aids", for a full description of all possible states.) You
must wait until the port is idle before retesting.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort and the port is not in use, escalate the
problem.
1005 ABORT The test was aborted due to a configuration problem. This code will result
under either of the following conditions:
1. This test may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the modem pool
member or music on hold).
2. The circuit pack is one of the following:
TN742 vintages 13,14 and 15
TN769 vintages 3,4 and 5
1008 ABORT Could not allocate a ringing circuit for one of the following reasons:
All the ringing circuits are in use, or
The ringing generator is defective, or
It is not wired correctly.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, look for RING-GEN errors in the Error Log.
If an ABORT 1008 occurs for Test #48 on other circuit packs as well,
then the ringing generator may be defective or not wired correctly. If it
does not occur on other ports, then that circuit pack is currently using
all four ringing phases.
Table 10-31. TEST #48 Station Present Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page