Maintenance Object Repair Procedures
Page 10-1427TSC-ADM (Administered Temporary Signaling Connections)
10
2000 ABORT The Administered TSC is not responding to a TSC heartbeat inquiry.
1. Retry the test tsc-administered command at one-minute intervals a
maximum of three times.
2. If the problem continues to fail, obtain the status of the D-channel or
D-channel pair associated with the ADMTSC via the status sig-group
<group> command. If the D-channel is INS (that is, in-service) and the
status of the ADMTSC appears to be active, disable and enable the
ADMTSC through administration. NOTE: To disable the ADMTSC,
display the (administration) Signaling Group Form via the change
sig-group <group> command where <group> refers to the number of
the signaling group under which the suspect TSC is administered.
Change the "Enable" field to "n." To enable the ADMTSC, change the
"Enable" field to "y."
3. Reissue the test tsc-administered command.
4. If the test fails, check the ADMTSC node on the other side of the
network to verify that the ADM TSC is indeed active.
5. Escalate the problem.
2012 ABORT Internal System Error.
1. Reissue the test tsc-administered command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1 FAIL The Administered TSC is not active (far-end).
1. Reissue the test tsc-administered command.
2. Verify that the Administered TSC node on the other side of the network
is active.
3. Disable and enable the Administered TSC.
4. Retry the test tsc-administered command.
5. If test fails, escalate the problem.
2 FAIL Facility IE (Information Element) reject.
1. Check all other nodes in the network, and make sure Administered
TSC is active.
2. Escalate the problem.
PASS The Administered TSC responded to a heartbeat.
Table 10-487. TEST #604 TSC Hartbeat Inquiry Test
Error
Code
Test
Result Description/ Recommendation
Continued on next page