Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-195reset system
8
Feature Interactions
The reset command invokes system initialization like low level
maintenance. Software never escalates requested reset levels.
Technicians determine the levels.
SHDW-CIR MAJOR ON or OFF 60 Warm
SHDW-LINK MAJOR ON 60 Warm
SW-CTL MINOR ON 40 Hot
PR-MAINT MINOR ON 30 Hot
PI-BD MAJOR or MINOR ON 20 Hot
PKT-CTRL MAJOR ON or OFF 20 Hot
PKT-CTRL MINOR ON or OFF 15 Hot
PI-PT MAJOR ON 15 Hot
DATA-CHL MINOR ON 15 Hot
DATA-CON MINOR ON 15 Hot
DATA-BD MINOR ON 15 Hot
MEM-CARD MINOR ON or OFF 10 Hot
PR-MAINT MINOR OFF 8 Hot
A reset system interchange command aborts if:
The standby SPE is down
The active SPE is locked active
Communication to the standby SPE is not possible
Memory shadowing to the standby SPE is not functioning
The standby SPE is not fully refreshed
The standby SPE is busied out
health-
override
If HOT restart interchanges fail because Fault Severity Levels of
standby SPEs are higher than active SPEs, the health-override
command tries to force a switch. If the switch occurs, new active
SPE Fault Severity Level raises to prevent a software-initiated HOT
SPE interchanger. This artificial raising of active Fault Severity Levels
lasts for one hour, then Fault Severity Levels of both SPEs returns to
their normal values.
Maintenance
Object Alarm Level
On/Off
Board
Fault
Severity Level
Restart
Level