DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-32change system-parameters maintenance
8
Suspension
Threshold
Some problems cause alarms to be generated and resolved
repeatedly. To detect these problems, the switch suspends Cleared
Alarm Notification when it has reported the specified number of
Cleared Alarm notifications in a 24 hour period. A suspended Cleared
Alarm Notification reactivates with a successfully-completed “logoff”
command, a system reset, or when the threshold is changed. This field
is irrelevant if Cleared Alarm Notification or Alarm
Origination are disabled. (1–15)
Test Remote
Access Port
Indicates if remote access testing on the SYSAM circuit pack is active.
This field should be set to yes when an INADS line is connected to the
switch and a maintenance contract is in effect to maintain alarm
origination capability.
If no equipment is connected to the remote access port, or if a trunk for
remote access and alarm origination is not provided, running tests on
the remote access port on the SYSAM results in test failures. This
causes unnecessary maintenance alarms and allows potentially
destructive tests to be run. To prevent this set this field to no.
CPE Alarm
Activation
Level
Indicates the minimum level (Major, Minor or Warning) to activate
Customer-Provided Equipment (CPE) alarm. If the level is none, the
CPE does not activate for any alarm. (none)
NOTE:
When the switch goes into Emergency Transfer, the CPE alarm
activates regardless of the CPE Alarm Activation Level setting.
Packet Bus
Activated
If this field is set to yes, maintenance software assumes that a Packet
Control circuit pack is installed. If packet endpoints (for example, ASAI,
and/or BRI) are administered, and maintenance testing runs on both
the Packet Control circuit pack and Packet Bus (set this field to yes
after a packet control circuit pack is installed.). If a Packet Control
circuit pack is not installed in the system, a major alarm is raised
against the PKT-CTRL MO.
Change this field from yes to no if no packet endpoints are
administered, to ensure that no packet endpoints can be administered
if the packet bus deactivated.
Set this field to yes after a Packet Control circuit pack is installed.
If a Packet Control circuit pack is not installed, then this field should be
set to no (the only exception is system translations that do not have all
required hardware). (no)
Customer Access
to INADS Port
To prevent customer login ID access to system administration and
maintenance interface control, set this field to no. Lucent Technologies
services has sole access to this field. (no)
Repeat Dial
Interval (MMS)
Number of minutes that the system must wait before attempting another
call origination to an OSS. Lack of a far-end acknowledgment triggers
the timer.