DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-363test maintenance
8
link, reset, and sanity functions on the EPN maintenance circuit pack. The long
test resets the EPN maintenance circuit pack, causing the EPNSAT link to be
dropped and is destructive.
Feature Interactions
The last test in the long test sequence on EPN maintenance circuit packs drops
the EPNSAT link.
1. If no alarms are registered against the maintenance object then the test sequence is run only once. The
long
clear
option forces a clear of all alarms if no errors are encountered during testing. The
short clear
option only
clears alarms pertinent to tests in the short sequence.
2. Refer to the Report Scheduler and System Printer feature specification for more details.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test
maintenance
location
short
long
repeat
number
clear
schedule
Physical location of the
maintenance circuit pack: (2-3)
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
Number of times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.
1
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.
2
Examples:
test maintenance 2
test maintenance 3 schedule
test maintenance 2 sh
test maintenance 2 l c
init
inads
craft
Test
sequence =
short;
repeat = 1
See below