Page 10-882M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286, G3iV2-386]
10
Only one value (Pass, Fail, or Abort) is generated as a result of the two tests. If
either fails or aborts, the sequence is stopped.
Table 10-297. TEST #13 Digital Port Loop Around Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort, escalate the problem.
1000 ABORT The port is in use on a valid ISDN-PRI Test Call. Use the list
isdn-testcall command to determine which call is using the port (from
the M/T Port column). Either wait for the test call to complete (as
indicated in the Start Time and Duration fields in the above display), or
abort the test call with the clear isdn-testcall tg/mem command, where
tg/mem is determined from the B-channel field of the above display.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort and the port is not in use, escalate the
problem.
1001 ABORT System resources required to run this test are not available.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions, or it may have time slots out-of-service
due to TDM-BUS errors. Refer to TDM-BUS Maintenance to diagnose
any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy
traffic, repeat the test at one-minute intervals a maximum of five
times.
2. If the test continues to abort, escalate the problem.
Continued on next page