Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-59display errors
8
Error List Enter one of the error lists below:
active-alarms (default)
errors
cleared-errors
The title for the Hardware Error Report includes the name of the
selected error list.
Interval Enter one of the codes below:
m = last month
h = last hour
d = last day (default)
w = last week
a = all
From Enter 2-digit numbers for the month/day/year (Example: 01/01/97).
The default is the earliest time of the existing error records in the log.
To Enter 2-digit numbers for the month/day/year (Example: 01/01/97).
The default is the current date.
Cabinet Enter 1, 2, or 3 (the administered number)
Port Network Enter 1, 2 or 3
Board
Number:
Enter a 5-digit equipment code for:
Cabinet = 01-03 (if omitted, the default is 01)
Carrier = A-E
Slot = 00-20
Example: 01A20
Port Enter a 7-digit equipment code for:
Cabinet = 01-03 (if omitted, the default is 01)
Carrier = A-E
Slot = 00-20
Circuit = 01-31
Example: 01A2031
Category Enter the object code for the equipment category. Press
HELP in this
field to view a list of the object codes
Extension Enter the extension number
Trunk Enter a group number or a group and member number:
Enter
only
the group number (01-99) to display
all
members in
the group. Example: 01/__
Enter
both
the group number (01-99) and member number
(01-99) to display a
specific
member in a group. Example:
01/99.