Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-328CONFIG (System Configuration)
10
CONFIG (System Configuration)
The System Configuration maintenance object (MO) oversees logical insertion
and removal of circuit packs in the system. When Switch Control detects that a
circuit pack is present in a port slot, it informs System Configuration and System
Configuration queries the circuit pack to determine the type and vintage of the
circuit pack. Similarly, when Switch Control detects that a circuit pack has been
removed from a port slot, it informs System Configuration.
There are no alarms or tests for System Configuration, but three types of errors
are logged to the Hardware Error Log (see below).
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. This error indicates that a Port circuit pack in the system did not respond
to a circuit pack type inquiry. Follow the procedures outlined in (b) to
determine if there is an error.
b. This error indicates that less than 25% of Trunk Group is available.
c. This error indicates that a Port circuit pack in the system did not respond
to a vintage inquiry.
As a result of either of these errors, a Port circuit pack may be physically
inserted in a Port slot, but the system may not recognize its existence. The
Error Type and Aux Data fields specify the location of the port circuit pack
that caused the error as indicated in Table 10-100. If the Error Type field is
greater than 1000, subtract 1000 from the Error Type field before
consulting the table.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run Full Name of MO
CONFIG none none System Configuration
System Configuration Error Log Entries
Error Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any none
2-117(a) 0-2 none
257(b) none
1002-1117(c) 0-2 none