DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1226SYS-PRNT (System Printer)
10
Make sure that the SYS-PRNT output device is
on-line
and
ready-for-service. Check the physical connectivity between the Data
Module and the SYS-PRNT output device or between the EIA port on the
backplane of the switch and the SYS-PRNT output device.
6. Verify that there are less than three active logins to the system. If this
condition exists, a login session must be terminated before the System
Printer Link can be established.
NOTE:
It is recommended that the System Printer Link be busied out before
executing maintenance tests over objects which compose the
System Printer Link. If the System Printer Link is busied out, then all
System Printer Link maintenance actions are deactivated.
Error Log Entries and Test to Clear Values
Notes:
a. System Technician has busied out the System Printer Link.
b. A failure was encountered while attempting to set up the System Printer
Link. This attempt could have been initiated by either the Report
Scheduler software or link maintenance [automatic link retry or the as the
result of a Link Retry Test (#215) request]. The Aux Data field contains the
following diagnostic information to aid in the correction of the failure:
1. unavailability of system resources (too many active logins to the
system).
2. no data channels (DATA-CHLs) available on the Network Control
circuit pack (DATA-BD).
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the
set options command.
Table 10-422. SYS-PRNT Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test sp-link
18 (a) 0 busyout sp-link WARNING OFF release sp-link
257 (b) 1 to 6 Link Retry Test
(#215)
MINOR/
WARNING
2
OFF test sp-link l
513 (c) 0 None MINOR OFF test sp-link