DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-665FL-DATA (Flash Data Consistency)
10
44 FAIL The update files, load vintages, and announcements are different in
both SPEs. The Active SPE has the most current update file and
announcements.
45 FAIL The update files, load vintages, translations, and announcements are
different in both SPEs. The Active SPE has the most current update
file, translations, and announcements.
46 FAIL The update files, load vintages, translations, and announcements are
different in both SPEs. The Active SPE has the most current update file
and announcements, and the Standby SPE has the most current
translations.
1. Follow the procedures for Error Code 4 to get the correct load
vintage. Be sure to save the announcements. After running the
test card-mem long command, check for Error Codes 32 or 64.
Follow the recovery procedure under the applicable error code.
48 FAIL The update files and announcements are different in both SPEs. The
Active SPE has the most current update file, and the Standby SPE has
the most current announcements.
1. Follow the procedures for Error Code 40.
49 FAIL The update files, translations, and announcements are different in both
SPEs. The Active SPE has the most current update file and
translations, and the Standby SPE has the most current
announcements.
50 FAIL The update files, translations, and announcements are different in both
SPEs. The Active SPE has the most current update file, and the
Standby SPE has the most current translations and announcements.
1. Follow the procedures for Error Code 41.
Table 10-223. TEST #421 Flash Data Consistency Check Test — Continued
Error Code
Test
Result Description/Recommendation
Continued on next page