DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-622EXP-INTF (Expansion Interface Circuit Pack)
10
3 ABORT The system could not allocate time slots for the test on either TDM Bus. The
system may be under heavy traffic conditions or it may have time slots
out-of-service due to TDM-BUS errors. Enter display errors and follow
associated repair procedures for TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, repeat
test at 1-minute intervals a maximum of 3 times.
1002 ABORT The system could not allocate time slots for the test on either TDM Bus. The
system may be under heavy traffic conditions or it may have time slots
out-of-service due to TDM-BUS errors. Refer to TDM-BUS (TDM Bus)
Maintenance documentation to diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, repeat
the test at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present or some Tone Detectors
may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If these errors are present, refer
to TTR-LEV (TTR Level) Maintenance documentation. Even if there are no
TTR-LEV errors, there still may not be a Tone Detector available on the
network that contains the circuit pack being tested. Verify that there is at
least one Tone Detector on this network. If not, this test always aborts for
this Expansion Interface circuit pack. This does not harm the system in
any way.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT
(Tone Generator) Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals a maximum
of 5 times.
1031 ABORT A query of the Expansion Interface circuit pack aborted. The purpose of this
query was to see if the Expansion Interface circuit pack could detect the
framing signal.
1. If Test #238 aborted, follow the procedure associated with this abort
code.
2. If Test #238 did not abort, rerun Test #240 at 1-minute intervals a
maximum of 5 times.
3. If Test #240 continues to abort without Test #238 aborting, escalate the
problem.
1032 ABORT The Expansion Interface circuit pack cannot detect the framing signal and
cannot run the test.
1. Refer to the errors for Test #238 to determine why the Expansion
Interface circuit pack is out-of-frame.
Table 10-211. TEST #240 EI Local Loop Around Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page