DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-56display disabled-tests
8
display disabled-tests
The display disabled-tests command lists the numbers for all maintenance tests
that have been disabled by INADS. These tests are not available for background
or demand testing.
Output
The following example shows the output from the display disabled-tests
command.
1. Refer to the Report Scheduler and System Printer feature specification for more details.
Remote Port
The application port used by the remote session.
Adjunct Name
The name of the adjunct connected to this processor channel.
These are defined in the Adjunct Name Form. Only AUDIX and
MSA channels require entries in this field: AUDIX, MSAAMWL,
MSAHLWC, MSALLWC, and MSAMCS.
Machine-ID
The network machine ID for the remote machine. Machine IDs
are required only for the AUDIX adjunct and DCS connections.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
display
disabled-tests
print
schedule
Report sent to printer
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue
and is executed at the specified
time. The information displayed
by the command is sent to the
system printer instead of the
screen.
1
init
inads
craft
cust
rcust
none none
display disabled-tests SPE A
DISABLED TEST INFORMATION
Test Number
710
Command successfully completed