Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-821MET-LINE (MET Line)
10
2 ABORT Internal System Error.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort, escalate the problem.
3 ABORT Station is in ready-for-service or out-of-service state. This may be due to
wiring or an unplugged or defective set.
1. Make sure terminal is connected and the wiring is correct.
2. Retry the command at 1-minute intervals a maximum of 5 times.
3. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not available. The port
may be busy with a valid call. Use the display port PCSSpp command
to determine the station extension, attendant number, or trunk
group/member number of the port. Use the status station, status
attendant, or status trunk command to determine the service state of
the port. If the service state indicates that the port is in use, then the
port is unavailable for certain tests. (Refer to the "Status Commands"
section in Chapter 8, ‘‘
Maintenance Commands and Trouble-Clearing
Aids’’ for a full description of all possible states.) You must wait until the
port is idle before retesting. Attendants are always in use (off-hook) if
the handset is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at one-minute
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
FAIL Internal System Error.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort, escalate the problem.
PASS MET Line Station Lamp Updates completed successfully.
1. If complaints still exist, investigate by using other circuit pack tests,
and by examining the station, wiring, and connections.
Table 10-275. TEST #60 MET Line Station Lamp Updates Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page