Page 10-1446UDS1-BD (UDS1 Interface Circuit Pack)
10
This error will isolate the board from the Packet Bus and raise an alarm. If
the Packet Bus is not alarmed, enter the following commands: busyout
board PCSS, reset board PCSS, test board PCSS, release board
PCSS. This should clear the alarm and restore the board to the Packet
Bus.
If the problem persists, and there are no PKT-BUS alarms, then replace
the circuit pack.
v. For later releases of G3V4 and beyond, only error 3073 will show that this
board is receiving slips and the AUX data shows the last slip count that
was reported.
w. These errors are not service-affecting. No action is required. These errors
are reported by the circuit pack when it receives a bad control channel
message from the switch. The auxiliary data identifies the following error
events:
x. For later releases of G3V4 and beyond, only error 3585 will show that this
board is receiving misframes and the AUX data shows the last misframe
count that was reported.
y. The UDS1 Interface circuit pack has detected a transient hardware logic
error (for example, program logic inconsistency). This error will disappear
when no faults are detected for 100 minutes. The value in Aux Data field
indicates the type of hardware problem.
z. Bad Translation RAM Location Found Error. This error is not
service-affecting. No action is required. A Bad Translation RAM is
detected, but the call continues by using another translation location.
aa. LAN Receive Parity Error. This error occurs when the circuit pack detects
an error in a received frame from the Packet Bus. These errors are most
likely caused by a Packet Bus problem, but may be due to a circuit pack
fault.
Refer to the PKT-BUS Maintenance documentation to determine if the
problem is isolated to this circuit pack or if the problem is caused by
Packet Bus faults.
4096 Bad major heading
4097 Bad port number
4098 Bad data
4099 Bad sub-qualifier
4100 State inconsistency
4101 Bad logical link