Maintenance Object Repair Procedures
Page 10-483DS1-BD (DS1 Interface Circuit Pack)
10
q. The hyperactive circuit pack is out-of-service and may exhibit one or more
of the following symptoms:
1. The common circuit pack level tests such as Test #51 and/or Test
#220 are aborting with error code 2000.
2. The tests run on the ports of this circuit pack are returning NO
BOARD.
3. A busy-out/release of the circuit pack has no affect on test results.
4. A list configuration command shows that the circuit pack and
ports are properly installed.
The circuit pack is isolated from the system and all trunks of this circuit
pack are placed into the out-of-service state. The system will try to restore
the circuit pack within 15 minutes. When no faults are detected for 15
minutes, the DS1 Interface circuit pack is restored to normal operation. All
trunks of the DS1 Interface circuit pack are then returned to the in-service
state. If the error recurs after 15 minutes, then replace the circuit pack.
r. For later releases of G3V4 and beyond, only error 3073 will show that this
board is receiving Slips and the AUX data shows the last Slip count that
was reported.
s. For later releases of G3V4 and beyond, only error 3329 will show that this
board is receiving misframes and the AUX data shows the last misframe
count that was reported.
t. This error is not service-affecting and can be ignored.
u. Error 3900 is used to give status information on a CPE Loopback Jack
Test. The value in the Aux Data field indicates the status of the loopback
test.
v. Error 3901 is used to give status information on a Far CSU Loopback Test.
The value in the Aux Data field indicates the status of the loopback test.
1
Test is currently running.
2
Test failed because loopback could not be activated.
3
Test failed because test pattern could not be detected.
4
Test has been terminated.
1
Test is currently running.
2
Test failed because loopback could not be activated.
3
Test failed because test pattern could not be detected.
4
Test has been terminated.