Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-737ISDN-SGR (ISDN-PRI Signaling Group)
10
Figure 10-53. PRI over PACCON Primary Signaling Link Hardware Check
(Test #636)
Table 10-243. TEST #636 Primary Signaling Link Hardware Check
Error
Code
Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1700 ABORT Rollabout video abort. The PRI terminal adapter associated with this
D-channel port is detached from the circuit pack. This is a normal abort
when the rollabout video feature is enabled. To complete test on this port,
either:
1. Re-attach the disconnected PRI terminal adapter and retry test
command, or
2. Disable the rollabout video feature on this circuit pack by entering
change ds1 PCSS and set the field "Alarm when PRI Endpoint
Detached?" to "y".
4 FAIL There is a problem with the Processor Interface Link. No DS1 ISDN Trunk
(B-channel) or wideband PRI Endpoint calls can be made until the problem
is resolved.
1. Display the Communication-Interface Links Form via the to determine
which link is down (find the one that matches the DS1 interface circuit
pack this ISDN-PRI Signaling Link Port is on) and then consult the
procedures for Processor Interface Link.
8 FAIL There is a problem with the DS1/UDS1 Circuit Pack, or the ISDN-PRI
Signaling Channel (D-channel). No DS1 ISDN Trunk (B-channel) or
wideband PRI Endpoint calls can be made until the problem is resolved.
1. Consult the procedures for DS1/UDS1 Circuit Pack and the ISDN-PRI
Signaling Channel (ISDN-LNK/ISDN-PLK).
Continued on next page
Packet Bus
To far end
switch hardware
Packet
Control
Circuit
Pack
(TN778)
UDS1
Interface
Circuit
Pack
(TN464*)
*TN464 C or later