Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Error Messages
Page A-116test duplication-interface
A
test duplication-interface
Help Messages
If the system technician presses HELP after entering "test duplication-interface," the
following message is displayed:
Enter [network(1);carrier(A-B) [’long’ or ’short’],
[’repeat’ (1-100) or ’clear’], [’schedule’]
Error Messages
For any system, if a user entered parameter is not among those listed in the "Parameters"
section, the following message is displayed:
Entry invalid
If an invalid port network is specified, the following message is displayed:
Invalid port-network specified
If an invalid carrier is specified, the following message is displayed:
Invalid carrier specified
If the standby is entering maintenance mode when this command is executed, then the
following message is displayed:
Cannot interrupt Standby SPE while entering
maintenance mode; please try later
If the standby SPE is not refreshed when this command is executed, then the following
message is displayed:
Standby SPE memory not refreshed;
use the "refresh spe-standby" command.
If the standby SPE is not refreshed and the active SPE is hard selected via the SPE
select switches when this command is executed, then the following message is
displayed:
Active SPE locked via select switches;
Standby SPE memory not refreshed
If the standby SPE is busy with another task, then the following message is displayed:
Standby SPE busy with another task;
for information use "status system 1"
If the standby SPE is not available when this command is executed, then the following
message is displayed:
Standby SPE not available;
for information use "status system 1"