Maintenance Object Repair Procedures
Page 10-918PDMODULE, TDMODULE (Data Module)
10
1000 ABORT System resources required to run test are not available. Port may be
busy with a valid call. Use display port PCSSpp command to
determine the data module extension. Then use status data module
command with the extension number to determine the service state of
the data module. If the service state indicates that the data module is in
use, then port is unavailable for certain tests. Wait until port is idle
before retesting.
1. If the port status is idle, retry the command at one-minute intervals
a maximum of five times.
2. If the test continues to abort, escalate the problem.
1001 ABORT System resources required to run this test are not available.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service
due to TDM-BUS errors. Refer to TDM-BUS (TDM Bus) Maintenance
documentation to diagnose any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy
traffic, repeat the test at one-minute intervals a maximum of five
times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a tone receiver for the test. The system
may be oversized for the number of Tone Detectors present or some
Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to
TTR-LEV (TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to
TONE-PT (Tone Generator) Maintenance documentation.
3. If neither condition exists, retry the command at one-minute
intervals for a maximum of five times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the
data module extension. Then use status data module command with
the extension number to determine the service state of the data
module. If the service state indicates that the data module is in use,
then the port is unavailable for certain tests. You must wait until the port
is idle before retesting.