DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-959PI-LINK (Processor Interface Link)
10
f. This error message indicates that the TN765 Processor Interface circuit
pack could not transmit the message the software sent to it. See the "Link
Recovery" section if the error continues. This is a normal error during "hot
start" SPE-interchanges.
g. Excessive resets on the link. Usually indicates that the remote end is down
or the physical connection is broken. A warning alarm is raised initially,
followed by a Major alarm if the problem is not cleared. See the "Link
Recovery" section.
32779
32782
32801
Administration problem; check that the Processor Interface
data module extension exists via the status data-module
<ext-no> command. Verify that the destination extension
exists and that the correct routing pattern is used. In
addition, check that the Processor Interface data module
and the destination extension are administered on the COS
and/or COR forms.
32813 Administration problem; check all administration.
32815 The off-premise call timed-out. Check the "Off-Premises
Tone Detect Timeout Interval" on the Feature-Related
System Parameters Form. The time-out is administered
between 6 and 25 seconds. No response was received
from the remote destination. Check the status of the remote
destination. This might also indicate possible
synchronization problems. Network synchronization
sources should be checked on all networked switches.
Also see the SYNC Maintenance documentation.
32814 Call was answered but not by a remote data module.
Check the remote destination extension and verify that this
is a data module.
32841 Call went over the trunk and received ring back but did not
receive modem answer tone. Check the remote destination
for automatic answering.
65528 Administration problem; check all administration.
65532 Call setup timed out; retry, and check destination. If the
destination is an adjunct (CMS, AUDIX, etc.), then check if
the terminal ready light is lighted on the PDM. If not, then
the adjunct is down. If the destination is another PBX, then
the PBX might be restarting. Retry.
65535 Link specified is out-of-range (1 through 8).