DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-910PDMODULE, TDMODULE (Data Module)
10
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. Could experience a noisy port or link. This is an off-board problem
detected by the port circuit. Check for faulty wiring, check for a defective
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. G3iV1.1-286 and G3iV2-386 only.
PDMODULE and TDMODULE Error Log Entries
Error Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1 (a) 40987 None WARNING OFF
1 (b) 1 to
20
None WARNING OFF
15 (c) Any None
18 (d) 0 busyout port PCSSpp WARNING OFF release port PCSSpp
257 (e) 40971 None
513
2
0 Data Module Audits
Test (#17)
WARNING (j) OFF test port PCSSpp sh r 6
769 (f) 40988 None WARNING OFF
1281 Any Data Module Audits
Test (#17)
WARNING OFF test port PCSSpp sh r 4
1537 (g) 40968 None WARNING OFF
1793 Information Channel
and Control Channel
Loop Around Test
(#13)
MINOR ON test port PCSSpp l r 3
2049 NPE Crosstalk Test
(#9)
MINOR ON test port PCSSpp l r 3
2305 (h) 32770 None
2305 (i) 40967 None
2561 Data Module Internal
Loop Around Test
(#175)
WARNING OFF test port PCSSpp l r 5
2817 (k) Link GPP Loop (183)
Against Links
MAJOR ON
3841 (l) NONE