DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1015PMS-LINK (Property Management System Link)
10
Link Retry Test (#215)
This test sends a message to the PMS software process to make a data call to
the extension where the PMS device connects. If the PMS Link is already up, then
this test passes without making any data call.
Table 10-346. TEST #215 Link Retry Test
Error
Code
Test
Result Description/ Recommendation
10
20
ABORT Internal System Error.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
30 ABORT Internal System Error.
1. Refer back to the ‘‘
Procedures for Restoring the PMS Link’’ section for
resolution.
1010 ABORT The PMS Link has been busied out and placed in the out-of-service state.
1. Enter release pms-link command to release the PMS Link from busyout
state.
2. Retry test pms command to execute the test.
FAIL The PMS Link CANNOT be established.
1. Refer back to the ‘‘
Procedures for Restoring the PMS Link’’ section for
restoring the PMS Link.
PASS The PMS Link is up.
Continued on next page