DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-373test pkt
8
Feature Interactions
The reset packet-control test (#586) does not run on the active packet-control.
This test is part of the standby packet-control test sequence, illustrated in the
screen output section below.
Output
The following example is the screen output for the test packet-control 1B long
command. Note that carrier B is the active carrier in this example.
Field descriptions
test pkt
The test pkt runs a series of tests on the Packet bus of the specified PPN or EPN.
Port Port address (cabinet-carrier-slot-circuit)
Maintenance
Name
The name of maintenance object.
Alt. Name Not applicable
Test No. The test number run on the packet-control.
Result Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test packet-control 1B l
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01B PKT-CTRL 583 PASS
01B PKT-CTRL 584 PASS
01B PKT-CTRL 585 PASS
Command successfully completed