DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-98ANN-BD (Announcement Circuit Pack)
10
Since this test involves sending a tone through two different ports, the Playback
Speech Memory Array (PSMA) Test (#206) [see ANN-PT (Announcement Port)
Maintenance documentation for a description of this test] is run on the two ports
first to make sure that they are working properly.
Table 10-36. TEST #210 140AY Loop Around Test
Error
Code
Test
Result Description/ Recommendation
1-3 ABORT Response to the test request was not received within the allowable time
period. The error code indicates at which speech compression rate the test
aborted (one being the first rate tested, three being the last).
1. Retry the command at one-minute intervals a maximum of five times.
10 ABORT The PSMA Test (#206) failed on Announcement Port 1.
90 ABORT The PSMA Test (#206) failed on Announcement Port 9.
1. Refer to"ANN-PT (Announcement Port)" Maintenance documentation,
Test #206.
1000 ABORT System resources required to run this test are not available. This test needs
Announcement Ports 1 and 9 to run. One of the ports may be in use on a
valid call.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort and Ports 1 and 9 are not in use, escalate
the problem.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors. Refer to "TDM-BUS (TDM Bus)" Maintenance
documentation to diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at one-minute intervals a maximum of five times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to the
"TTR-LEV (TTR Level)" Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to the
"TONE-PT (Tone Generator)" Maintenance documentation.
3. If neither condition exists, retry the test at one-minute intervals a
maximum of five times.
Continued on next page