DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-383test shadow-link
8
Output
The following output example is for the test processor a command. The
responses display on a test-by-test basis with one line of data for each test result.
Field descriptions
test shadow-link
This command performs hardware diagnostics for the shadow link between the
two duplication-interface circuit packs. This command works only with High or
Critical Reliability systems. Refer to Chapter 6, ‘‘
Reliability Systems: A
Maintenance Aid’’ for more details.
Port The port address (cabinet-carrier) of the maintenance object that
is being tested.
Maintenance
Name
Maintenance object being tested is MEMORY.
Alt. Name Not applicable.
Test No. Test being executed
Result Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test processor a SPE B
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01A PROCR 77 PASS
01A PROCR 80 PASS
01A PROCR 82 PASS
01A PR-MAINT 102 ABORT 1018
01A PR-MAINT 103 ABORT 1018
01A PR-MAINT 106 PASS
01A PR-MAINT 228 PASS
01A PR-MAINT 229 ABORT 1018
01A MEMORY 87 PASS
01A MEMORY 631 PASS
Command successfully completed