DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-793MAINT (EPN Maintenance Circuit Pack)
10
NOTE:
The status of the link is changed to "down" when the Standby Expansion
Interface circuit pack begins initialization tests (for example, after being
reseated). The link status is then updated at the conclusion of these tests.
Table 10-265. TEST #337 EPN Maintenance Circuit Pack Serial Link Test
Error
Code
Test
Result Description/Recommendation
1030 ABORT The active Expansion Link to the EPN Maintenance circuit pack is not
running.
1. Follow up on the test results of the EPN Maintenance Circuit Pack
Sanity Handshake Test (#105).
2. When problems associated with this test are resolved, rerun Test
#337.
1035 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1036 ABORT There is no Standby Expansion Link running. Either the system only has
one Expansion Link, the Standby Expansion Link is down due to
Expansion Link, or the Expansion Interface circuit pack problems.
1. Issue the status system command and determine if the Standby
Expansion Link is down or does not exist. If it does not exist, dashes
are shown. Otherwise, the link status is shown. If there is no Standby
link, this test always aborts.
2. If there is a Standby link and it is down, then refer to EXP-INTF
(Expansion Interface Circuit Pack) Maintenance documentation and
resolve all alarms on the link.
3. Rerun the test.
2033 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page