DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1452UDS1-BD (UDS1 Interface Circuit Pack)
10
Table 10-492. TEST #53 SAKI Sanity Test
Error
Code
Test
Result Description/ Recommendation
None ABORT System resources required for this test are not available.
1. Retry the reset board command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, escalate the problem.
1005 ABORT Wrong circuit pack configuration to run this test. This error applies only to
DS1 Interface circuit packs. It means the DS1 Interface circuit pack is
providing timing for the system and, therefore, it cannot be reset without
major system disruptions.
1. If the circuit pack needs to be reset, then set synchronization to
another DS1 Interface circuit pack or to the Tone-Clock circuit pack
and try again. Refer to SYNC (Synchronization) Maintenance
documentation.
1015 ABORT Port is not out-of-service.
1. Busyout the circuit pack.
2. Execute the reset board command again.
3. If the test aborts with this error code again, escalate the problem.
2100 ABORT System resources required for this test are not available.
1. Retry the reset board command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, escalate the problem.
1 FAIL The circuit pack failed to reset.
2 FAIL The circuit pack failed to restart.
1. Execute the reset board command again.
2. If the problem persists, replace the circuit pack.
PASS The circuit pack initializes correctly.
1. Run the Short Test Sequence.
Continued on next page