Maintenance Object Repair Procedures
Page 10-1424TSC-ADM (Administered Temporary Signaling Connections)
10
b. The port field in the error log contains the signaling group number for
TSC-ADM errors.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the following tables when
inspecting errors in the system. By clearing error codes associated with the
TSC
Heartbeat Inquiry Test,
for example, you may also clear errors generated
from other tests in the testing sequence.
TSC Heartbeat Inquiry Test(#604)
This test can be invoked by system technician personnel for any ADMTSC
administered in the switch. The following table indicates the possible error
conditions that might be encountered when the test is invoked. Most of the error
conditions do not log an error, but switched services may take some type of
recovery action in certain instances.
This test sends a USER INFORMATION TSC heartbeat message inquiry across
an Administered TSC to determine if the far-end can respond to a USER
INFORMATION TSC heartbeat message.
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
TSC Heartbeat Inquiry Test (#604) ND
Table 10-487. TEST #604 TSC Hartbeat Inquiry Test
Error
Code
Test
Result Description/ Recommendation
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Reissue the test tsc-administered command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page