Maintenance Object Repair Procedures
Page 10-922PDMODULE, TDMODULE (Data Module)
10
Data Module Internal Loop Around Test (#175)
This test verifies that a data message can be sent from the PBX, through the
building wiring, through an internal looparound path in the data module under
test, and back to the PBX. Figure 10-75
shows the hardware configuration used
for this test.
5 ABORT Ringer update aborted (data module not in the in-service state).
1. Verify that the data module is powered (power LED on).
2. Make sure data module is connected to the building wiring, check for
faulty wiring, check for faulty data module.
3. Retry the command at one-minute intervals a maximum of five times.
4. Replace the Data Module and repeat the test.
5. If the test continues to abort, replace the Digital Line circuit pack and
repeat the test.
6. If the test continues to abort, escalate the problem.
6 ABORT Data module translation update aborted.
1. Verify the data module is connected to the PBX.
2. Retry the command at one-minute intervals a maximum of five times.
3. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not available.
2000 ABORT Response to the test request was not received within the allowable time
period.
FAIL Internal System Error.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to fail, escalate the problem.
PASS Data Module Audits passed. This digital port circuit pack is functioning
properly.
1. If complaints still exist, investigate by using other port tests, and by
examining the data module options, wiring, and connections.