DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-895OPS-LINE (DS1 OPS Line)
10
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate associated
errors (if any).
b. The DS1OPS Line has been busied out by a busyout station <ext>
command. No calls can be made on this line.
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
d. Error Type 1793 indicates a problem with the DS1 Interface circuit pack.
Since there is no error against the OPS-LINE port, no alarm is raised
against the OPS-LINE port. However, there should be errors logged
against the DS1 Interface circuit pack. Look for DS1-BD errors in the
Hardware Error Log and follow procedures provided in the DS1-BD (DS1
Interface Circuit Pack) Maintenance documentation.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
DS1 OPS Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test station <ext> sh r 1
15 (a) Any Audit and Update
Test (#36)
18 (b) 0 busyout station <ext> WARNING OFF release station <ext>
130 (c) None WARNING ON test station <ext>
1281 Conference Circuit
Test (#7)
MINOR ON test station <ext> l
1537 NPE Crosstalk Test
(#6)
MINOR ON test station <ext> l
1793 (d) test circuit pack PCSS l