DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1560XXX-BD (Common Port Circuit Pack)
10
2000 ABORT There was no response from the board.
1. If error type 1538 (hyperactivity) is present in the error log, follow the
maintenance strategy that is recommended for this error type.
2. Run the busyout board, reset board, and release busy board
commands,and then retest.
3. If the test still aborts, dispatch with the circuit pack.
4. Check the off-board wiring and the terminal, and, if there are no
problems found, replace the circuit pack.
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the station
extension. Use the status station command to determine the service state
of the port. If the service state indicates that the port is in use, the port is
unavailable for certain tests. (Refer to the "Status Commands" section in
Chapter 8, ‘‘
Maintenance Commands and Trouble-Clearing Aids’’ for a full
description of all possible states.) You must wait until the port is idle before
retesting.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort and the port is idle, escalate the problem.
1008 ABORT Could not allocate a ringing circuit for one of the following reasons: all the
ringing circuits are in use; the ringing generator is defective; ringing
generator is not wired correctly.
1. If the test continues to abort, look for RING-GEN error in Error Log.
a. If there are RING-GEN errors, refer to RING-GEN Maintenance
documentation and try to resolve any problem(s). Go to Step 2.
b. If there are no RING-GEN errors, and the test continues to abort,
issue the test board PCSS command on other TN742, TN769, or
TN746 Analog circuit packs. If an ABORT with error code 1008
occurs for this test on other circuit packs as well, the ringing
generator may be defective or may not be wired properly. Refer to
RING-GEN Maintenance documentation for details. If an ABORT
with error code 1008 does NOT occur on the other ports, then all
four ring generators are in use. Exit from this documentation.
2. Retry the command.
3. If the test continues to abort, escalate the problem.