DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-326CO-TRK (CO Trunk)
10
1941 ABORT High frequency singing return loss self check failed.
1. Test the TN771 circuit packs.
2. If the test continues to abort escalate the problem.
1942 ABORT Echo return loss self check failed.
1. Test the TN771 circuit packs.
2. If the test continues to abort escalate the problem.
1943 ABORT Singing return loss self check failed.
1. Test the TN771 circuit packs.
2. If the test continues to abort escalate the problem.
1944 ABORT Loss self check at -16 dBm at 1004 Hz failed.
1. Test the TN771 circuit packs
2. If the test continues to abort escalate the problem.
1945 ABORT Loss self check at -16 dBm at 404 Hz failed.
1. Test the TN771 circuit packs.
2. If the test continues to abort escalate the problem.
1946 ABORT Loss self check at -16 dBm at 2804 Hz failed.
1. Test the TN771 circuit packs.
2. If the test continues to abort escalate the problem.
1947 ABORT Noise with tone self check failed.
1. Test the TN771 circuit packs.
2. If the test continues to abort escalate the problem.
2000 ABORT The test timed out while waiting for a response from the TN771 circuit
pack.
1. Retry the command at 1 minute intervals for a maximum of 5 retries.
2. If the test continues to abort escalate the problem.
2012 ABORT An internal software error occurred.
1. Retry the command at 1 minute intervals for a maximum of 5 retries.
2. If the test continues to abort escalate the problem.
2053 ABORT The test call could not be established, but no information on why is
available.
1. Retry the command at 1 minute intervals for a maximum of 5 retries.
2. If the test continues to abort escalate the problem.
Table 10-106. TEST #844-848 Transmission Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page