Maintenance Object Repair Procedures
Page 10-239CARD-MEM (Memory Card)
10
Does the inserted memory card contain the Announcement file for a
system with an Announcement circuit pack?
Does the size of the translations in the system reach 98% of the reserved
storage space on the memory card?
If the answer to any of these questions is "yes," maintenance raises a WARNING
alarm for service attention. A new memory card is usually required.
Table 10-84. TEST #697 Memory Card Match Test
Error
Code
Test
Result Description/ Recommendation
2012
2106
2114
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2013
2100
none
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2108 ABORT The NETCON circuit pack is not a TN777B circuit pack.
1. Follow the Standard Repair Procedures for replacing the NETCON
circuit pack with the TN777B circuit pack.
2. Re-enter the test card-mem command.
2110 ABORT No memory card is inserted.
1. Insert a formatted memory card into the slot at the TN777B NETCON
circuit pack.
2. Rerun the test.
2111 ABORT Inserted memory card is not formatted.
1. Insert a formatted memory card into the slot at the TN777B NETCON
circuit pack.
2. Rerun the test.
101 FAIL The inserted memory card is a system-upgrade memory card.
1. Replace the memory card with a user’s memory card.
2. Retry the command at 1-minute intervals a maximum of 5 times.
102 FAIL The inserted memory card does not contain an Announcements file, and
the system is configured with the Announcement feature.
1. Replace the memory card with a 10 MB memory card.
2. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page