Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-237status cleared-alarm-notif
8
Output
The following example is a display of the status cdr-link command.
Field descriptions
status cleared-alarm-notif
Expert systems use the status cleared-alarm-notif command to detect chronic
alarming conditions. If this command displays “Feature is suspended”, Expert
Systems can identify open trouble tickets as chronic problems for special
consideration.
Link State
Up, down, or unadministered extension.
“up” = link is up and available to the application. (normal state)
“down” = link is physically down.
“Extension not administered” = administer system cdr feature
form.
Number of Retries
The number of times the switch tries to initialize the link.
Maintenance Busy
“yes” = maintenance object is busied out. “no” = maintenance
object is not busied out.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
cleared-alarm-
notif
1
2
First OSS telephone number
status of Cleared Alarm
Notification.
Second OSS telephone number
status of Cleared Alarm
Notification.
Examples:
status cleared-alarm-notif
status cleared-alarm-notif 1
status cleared alarm-notif 2
init
inads
craft
cust
rcust
first OSS
telephone
number for
the Cleared
Alarm
Notification
status.
none
status cdr-link
CDR LINK STATUS
Primary Secondary
Link State: up extension not administered
Number of Retries: 0
Maintenance Busy? no