DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1383TIE-TRK (Tie Trunk)
10
Tie Trunk EPF Test (#74)
This test consists of an E lead and M lead test. The E lead test checks for the
proper activation and deactivation of the port’s E lead. The M lead test checks
the M lead EPF current flow. The processor sends an M lead test request to the
circuit pack and receives the results. The returned results are measured to see if
a port or external tie trunk line fails.
PASS The relevant seizure test passes. This port is functioning properly.
1. If users are reporting troubles, examine loop connections to the port,
wiring, and stations.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
Table 10-480. TEST #74 Tie Trunk EPF Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run the test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1 ABORT Internal System Error.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page
Table 10-479. Seizure Tests (#73, #747, #73) — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page