Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1271TAPE-DAT (Tape Consistency)
10
73 FAIL The update files, translations, and announcements are different in both
SPEs. The Active SPE has the most current translations and
announcements, and the Standby SPE has the most current update file.
74 FAIL The update files, translations, and announcements are different in both
SPEs. The Active SPE has the most current announcements, and the
Standby SPE has the most current update file and translations.
1. Issue the save translations command.
2. Issue the save announcements command.
3. Follow the procedures for Error Code #64.
76 FAIL The update files, load vintages, and announcements are different in both
SPEs. The Active SPE has the most current announcements, and the
Standby SPE has the most current update file.
77 FAIL The update files, load vintages, translations, and announcements are
different in both SPEs. The Active SPE has the most current translations
and announcements, and the Standby SPE has the most current update
file.
78 FAIL The update files, load vintages, translations, and announcements are
different in both SPEs. The Active SPE has the most current
announcements, and the Standby SPE has the most current update file and
translations.
1. Follow the procedures for Error Code #4 to get the correct load
vintage. After running the test tape long command, check for Error
Code #32 or #64. Follow the recovery procedure under the applicable
error code.
80 FAIL The update files and announcements are different in both SPEs. The
Standby SPE has the most current update file and announcements.
1. Issue the save announcements command to save announcements on
both SPEs.
2. Follow the procedures for Error Code #64.
81 FAIL The update files, translations, and announcements are different in both
SPEs. The Active SPE has the most current translations, and the Standby
SPE has the most current update file and announcements.
82 FAIL The update files, translations, and announcements are different in both
SPEs. The Standby SPE has the most current update file, translations, and
announcements.
1. Issue the save translations command.
2. Issue the save announcements command.
3. Follow the procedures for Error Code #64.
Table 10-437. TEST #421 Tape Data Consistency Check Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page