DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-213set vector
8
■ A system restart occurs on the active SPE in a High or Critical Reliability
system with the corresponding vector bit set.
■ The active SPE-active option is selected when the vector bit is set.
!
CAUTION:
This command disrupts service in a simplex system.
The active SPE executes a core dump when:
■ A system restart occurs on the active SPE in a High or Critical Reliability
system with the corresponding vector bit set.
■ The SPE-standby option is selected when the vector bit is set.
The active SPE executes a core dump when:
■ A system restart occurs on the active SPE in a High or Critical Reliability
system with the corresponding vector bit set.
■ The active SPE-maint option is selected when the vector bit is set.
The vector clears after all core dumps.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
set vector
spe-standby
spe-active
spe-maint
see below.
SIMPLEX SYSTEM
Examples:
set vector f
set vector 9
DUPLEX SYSTEM
Examples:
set vector f
spe-standby
set vector f
spe-active
set vector f spe-maint
set vector 9
init
inads
craft
spe-standby
(High or
Critical
Reliability
Systems)
none
Vector-Condition Mapping
value WARM COLDII COLDI REBOOT
0n n n n
1y n n n
2n y n n
3y y n n
4n n y n
5y n y n
6n y y n