Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Error Messages
Page A-53release cdr-link
A
If a board is not inserted in the specified location, the following message will be
displayed:
Board not assigned
If the specified board does not have any maintenance objects associated with it, the
following message will be displayed:
No MO in this board
If the specified board is a EI board and it is part of the active link, the following message
will be displayed:
Illegal Command for active object; use ’set’ to switch to
standby
If a reset is attempted on an invalid board in the service slot, the following message is
displayed:
Board invalid
If the command entered is in conflict with another currently executing command, then a
message will be displayed showing the login id of the conflicting user and the conflicting
command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires the user
to restart the command, then the following message will be displayed:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the following
message will be displayed:
All maintenance resources busy; try again later
release cdr-link
Help Messages
If the system technician presses HELP after entering "release cdr-link," the following
message will be displayed:
Enter ’primary’ or ’secondary’
Error Messages
If the cdr-link is not administered, then the following message will be displayed:
Link not administered