DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-660FL-DATA (Flash Data Consistency)
10
Notes:
a. See “CARD-MEM” for this test description.
b. See “12V-PWR” for a description of this test.
c. The Flash Data Consistency Test does not run in a Standard system.
Flash Data Consistency Check Test (#421)
The software vintage number, translation time stamps, announcement time
stamps, and update file time stamps and identifiers are read off of both memory
cards or SPEs and then compared. If the comparison shows any discrepancy,
FL-DATA is alarmed. This test is only run in a High or Critical Reliability system.
The test is run as part of the test card-mem long and as part of the standby PE
scheduled maintenance.
Table 10-223. TEST #421 Flash Data Consistency Check Test
Error Code
Test
Result Description/Recommendation
0 ABORT The test timed out without completing. This error can occur when the
system is heavily loaded and the test is not allocated sufficient time to
run.
1. Rerun the test when the system is less busy and is not running
standby maintenance.
1029 1030
2011 2012
2013 2014
2015 2016
2017 2018
2019 2020
2021 2022
2023 2024
2025 2051
ABORT Refer to the STBY-SPE (Standby SPE) Maintenance documentation for
a description of these error codes.
9005 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
35498 ABORT Difficulty was encountered trying to send information between the
SPEs.
35512 ABORT The Standby SPE cannot be put into maintenance mode.
1. Check for and resolve all DUPINT (Duplication Interface Circuit
Pack), SHDW-LNK (Memory Shadowing Link), SHDW-CIR
(Common Shadow Circuit), and STBY-SPE (Standby SPE) alarms.
2. Retry the command.
Continued on next page