DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-71ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)
10
1018 ABORT Test disabled via administration. The default for the ’Test’ field on the
’Station’ form is ’y’; thus, you may want to determine why this field has been
set to ’n’ on this station (this may be due to the ringing application test 48,
which can be customer or terminal disturbing).
1. To enable the test for a particular station, enter change station
extension and set the ‘Test?’ field on the ‘Station Form’ to ‘y.’
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available. Either a system
allocation to get information about the port or to put the port into a service
state failed or the attempt to put the port in connection with a tone source
failed (this could be a tone-clock problem). The tone-clock and tone
detectors could be having a communication problem, for example, the
companding modes could be out of synchronization.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The port’s battery feed chip is unable to supply sufficient power to the
terminal equipment. This may occur when the test is performed at the same
time that the terminal equipment goes off-hook.
1. Use status station to determine when the port is available for testing.
When the port becomes available for testing, retry the command at
1-minute intervals a minimum of five times.
2. If the test continues to fail, determine whether the customer is
experiencing problems on this line. Replace the circuit pack only if the
customer is experiencing problems.
PASS The port’s battery feed chip is able to provide power to the station
equipment to detect on-/off-hook. However, the battery feed chip may still
be unable to provide power for touch-tones. If tones are heard when
buttons are pressed, then the battery feed chip is functioning correctly;
otherwise, replace the circuit pack because this port is defective.
User-reported troubles on this port should be investigated by using other
port tests, by examining station wiring, by examining the station, and by
ensuring that the terminal is correctly translated as off-premises or
on-premises.
NOTE:
This test always passes for TN712 Analog circuit packs prior to
Vintage 14 and TN742 prior to Vintage 6.
Table 10-28. TEST #35 Battery Feed Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page