DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-108ANN-PT (Announcement Port)
10
2. An announcement download is invoked sooner with the administration
terminal restore announcements command.
3. There is no announcement and/or NETCON data module administered.
4. Either the announcement data module is busy or all the administered
NETCON data modules are busy.
5. There is no tape in the system.
6. The tape in the system does not have a valid announcement file saved
on it.
NOTE:
Unlike translations, there is no provision in the system for automatically
saving announcements to the system tape.
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
Table 10-39. Announcement Port Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1 Playback Speech Memory
Array (PSMA) Test (#206)
MINOR ON test port PCSSpp sh r 3
18 0 The port was busied out WARNING OFF release port PCSSpp
130 (a) None WARNING ON test port PCSSpp sh
257 Channel Administration
Memory Array (CAMA)
Test (#205)
MINOR ON test port PCSSpp l r 3
17667 In-line error
513 140AY Channel Sanity
Inquiry Test (#222)
MINOR ON test port PCSSpp sh r 3
17684 In-line error
769 (b) None