DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Error Messages
Page A-144test tsc-administered
A
If all of the available maintenance resources are currently in use, then the following
message will be displayed:
All maintenance resources busy; try again later
test tsc-administered
Help Messages
If the system technician presses HELP after entering "test tsc-administered" the following
message will be displayed:
Enter group # (1-8) or group #, [/tsc index (1-64)],
[’repeat’ (1-100)], [’schedule’]
Error Messages
If the format for the specified signaling group or the signaling group and TSC is
incorrect, the following message is displayed:
Format invalid
If the specified signaling group number is out of range, the following message is
displayed:
Signaling group invalid
If the specified signaling group is not administered, the following message is displayed:
No signaling group assigned
If the specified signaling group has no TSC assigned or the specified TSC is
unadministered, the following message is displayed:
No TSC assigned
If the specified TSC number is out of range, the following message is displayed:
Tsc index invalid
If the software data cannot be sent to the SAT, the following message is displayed:
Error encountered, can’t complete request
If no tests can be found for the associated MO, the following message is displayed:
No tests for this MO
If the command entered is in conflict with another currently executing command, then a
message will be displayed showing the login id of the conflicting user and the conflicting
command. The message is as follows:
’login id’:’command’ has a command conflict