Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1344TDM-CLK (TDM Bus Clock)
10
Set the PPM threshold at 60 PPM for TN768 and TN780. Set the PPM
threshold at 85 PPM for TN2182.
Enable PPM threshold switching
Set the number of slips to trigger
loss of signal
- currently 30 per 5
millisecond period
Enable the on-board synchronization switching algorithm (see above)
Enable holdover operation (TN2182 only).
This is not a test and will always pass without identifying or reporting any
Tone-Clock circuit pack errors
Board Type Check Test (#574)
This test verifies that a Tone-Clock circuit pack administered with a Stratum 3
Clock source has code TN780
Table 10-468. TEST #151 TDM Bus Clock Parameter Update Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error
FAIL Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The Tone-Clock circuit pack parameters have been successfully updated.
Continued on next page
Table 10-469. TEST #574 Board Type Check Test
Error
Code
Test
Result Description/ Recommendation
2012 ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5 times.
ANY FAIL Stratum 3 Clock Synchronization is administered for the carrier in which this
Tone-Clock circuit pack resides, but the Tone-Clock does not have code
TN780.
1. If the Stratum 3 Clock option is incorrectly administered, remove it.
2. Otherwise, replace the circuit pack. See
How to Replace the
Tone-Clock Circuit Pack
in the TONE-BD section.
Continued on next page