DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-570E-DIG-BD (Multi Application Platform Board)
10
E-DIG-BD (Multi Application
Platform Board)
The maintenance strategy for DIG800-BD is the same as the one described for
MO-COMBD (MO-XXX-BD). Maintenance testing of the common circuit pack is
handled by on-board firmware and SPE controlled tests. Maintenance software
queries the firmware for error and alarm information, status, and test results. The
firmware automatically reports error conditions that will result in SPE-controlled
testing.
Board Insertion
The switch makes an additional board query if any of the following circuit packs
are inserted:
For any of the above initial board up-links, the switch sends queries requesting
additional data from the board for administration purposes, while also telling the
board the switch software release and the system type.
For the native mode, the response to the board query downlink messages
consists of several CCMS uplink messages that identify the true board code,
vintage, suffix, emulation type, and the number of reserved slots it needs.
1. Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier
designation (for example, A, B, C, or D); and SS is the address of the slot in the carrier
where the circuit pack is located (for example, 01, 02, ...).
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
Full Name of MO
DIG800-BD MIN test board PCSS sh MO800DIG-BD
DIG800-BD WRN test board PCSS sh MO800DIG-BD
Circuit Pack Vintage
TN754 49
TN556 49,
80 or greater
TN800 any