Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-319CO-TRK (CO Trunk)
10
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized force.
1. Look for TTR-LEV errors in the Error Log. If present, refer to TTR-LEV
Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT
Maintenance documentation.
3. If neither condition exists, retry the command at one-minute intervals a
maximum of five times.
4. If the test continues to abort, escalate the problem.
1004 ABORT System resources required to run this test are not available. The port may be
busy with a valid call. Use the display port PCSSpp command to determine
the trunk group/member number of the port. Use the status trunk command
to determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait until
the port is idle before retesting.
1. If the port status is idle, retry the command at 1 minute intervals for a
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1018 ABORT The test was disabled via administration. Verify that the ’Maintenance Test’
field on the ’Trunk Group’ form is set to ’n’. To enable the test, issue the
’change trunk-group x’ command (x equals the number of the trunk group to
be tested). Then, change the entry in the ’Maintenance Test’ field on the form
to ’y’.
1. Retry the command at 1 minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
2000 ABORT Response to the test was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-104. TEST #33 Loop Around and
Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page