Maintenance Commands and Trouble-Clearing Aids
Page 8-352test inads-link
8
test inads-link
This command attempts to make a call over the inads port on the maintenance
board to verify the INADS alarm notification process. In the default settings, the
system test the link to the first OSS telephone number. If there is an alarm
pending to be reported or the call is in progress or up, then the test aborts. If the
alarm origination to the OSS telephone number to be tested is disabled, then the
test generates an informative error and the test continues. The test waits 2
minutes before dialing the call to allow the remote maintenance technician to
logoff, thus freeing the line. A
local
SAT user entering the test inads-link
command does not need to log off for the system to place the call, but the
two-minute delay still exists.
Once the call is answered by INADS, the system sends a message with a test
alarm type. INADS acknowledges receipt of the message and creates a trouble
ticket. The trouble ticket is closed immediately and has a “INADS LINK TEST”
message entered in the description field. If an alarm is raised while the test call is
up, the system does not send an alarm message over the existing link. The
normal retry mechanism is followed, which means an attempt to make a call to
INADS to report the error takes place 7 minutes later. An INADS trouble ticket is
created only if the connection is successfully established and a message is sent
to the system acknowledging that INADS received the system message.
The Maintain Process Circuit Packs field must be set to yes on the inads
and technician permission forms. This provides permissions to execute the test
inads-link command. This field can be changed by executing a change
permission login command.
No alarms are raised on the system and attendant alarm and acknowledgment
lamp states are not changed as a result of the test inads-link command. The test
does not run during periodic or scheduled maintenance.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test inads-link 1
2
First OSS telephone number
Second OSS telephone number
Examples:
test inads-link
test inads-link 1
test inads-link 2
init
inads
craft
nms
1st OSS
number
none
test hardware-group system
Command started in background mode