Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1450UDS1-BD (UDS1 Interface Circuit Pack)
10
Control Channel Loop Around Test (#52)
This test queries the circuit pack for its circuit pack code and vintage and verifies
its records.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the add ds1
PCSS command to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the
board is shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 10-491. TEST #52 Control Channel Loop Around Test
Error
Code
Test
Result Description/ Recommendation
None
2100
ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
Continued on next page
Table 10-490. TEST #50 NPE Connection Audit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page