Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-370test network-control
8
Output
The following example shows the output from the test network-control a
command. The responses display on a test-by-test basis with one line of data for
each test result.
Field descriptions
Port Port address: cabinet (always 1)-carrier-slot-circuit. For the
DATA-BD, SW-CTL, 12V-PWR, and CARD-MEM maintenance
objects, the slot and circuit fields of port address are blank.
DATA-CHL (administered data channel) uses XX as the slot
address and has a circuit number between 01 and 04. The carrier
field has a value A for the control carrier A in a simplex system,
and A or B for control carriers A and B in a duplex system.
Maintenance
Name
The name of the maintenance object:
DATA-BD for Network Control board
SW-CTL for Switch Control Archangel
DATA-CHL for administered data channel
12V-PWR for 12 volt power supply unit on the Network Control
board
CARD-MEM for flash memory card on Network Control board
12V-PWR and CARD-MEM (shown only when the Network
Control board is TN777B)
test network-control a
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01A DATA-BD 52 PASS
01AXX01 DATA-CHL 4001 109 PASS
01AXX01 DATA-CHL 4001 110 PASS
01AXX01 DATA-CHL 4001 111 PASS
01A SW-CTL 95 PASS
01A SW-CTL 92 PASS
01A SW-CTL 94 PASS
01A SW-CTL 324 PASS
01A 12V-PWR 701 PASS
01A CARD-MEM 695 PASS
01A CARD-MEM 696 PASS
01A CARD-MEM 697 PASS
01A CARD-MEM 698 PASS
01A CARD-MEM 699 PASS
Command Successfully Completed