DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-292CO-DS1 (DS1 CO Trunk)
10
1004 ABORT The port has been seized by a user for a valid call. Use the status station
or status trunk command to determine when the port is available for
testing.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, and the port is not in use, escalate the
problem.
1018 ABORT The test was disabled via translation. You may want to determine why the
test has been disabled before you enable it.
1. Verify that the ’Maintenance Test’ field on the ’Trunk Administration’
screen is set to 'n.’ To enable the test, change the trunk administration
and enter 'y' into the 'Maintenance Test' field.
2. Repeat the test.
1020 ABORT The test did not run due to a previously existing error on the specific port or
a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit
pack and attempt to diagnose the previously existing error.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
2053 ABORT At least one of the following errors was found on the DS1 circuit pack: loss
of signal (1281), blue alarm (1793), red alarm (2049), yellow alarm (2305),
or hyperactivity (1537).
1. Look for the above error types in the Hardware Error Log and follow
the procedures given in the appropriate DS1-BD or UDS1-BD
maintenance documentation for the listed error types.