DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1362TIE-DS1 (DS1 Tie Trunk)
10
5. The outgoing signal type of the trunk is either automatic or
immediate-start.
Table 10-474. TEST #136 DS1 Tie Trunk Seizure Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error.
1000 ABORT System resources required to run this test were not available. The port may
be busy with a valid call. Use the display port UUCSSpp command to
determine the trunk group/member number of the port. Use the status
trunk command to determine the service state of the port. If the service
state indicates that the port is in use, then the port is unavailable for certain
tests. You must wait until the port is idle before retesting.
1. If the port status is active but the port is not in use (no calls), check the
error log for error type 1025 (see the error log table for a description of
this error and required actions). The port may be locked up.
2. If the port status is idle, retry the command at 1 minute intervals for a
maximum of 5 times.
3. If the test continues to abort, escalate the problem.
1004 ABORT Far end is seizing the trunk while the test is ongoing. A glare situation is
detected. Current test is designed to be aborted. Use the display port
UUCSSpp command to determine the trunk group/member number of the
port. Use the status trunk command to determine the service state of the
port. If the service state indicates that the port is in use, then the port is
unavailable for certain tests. You must wait until the port is idle before
retesting.
1. If the port status is idle, retry the command at 1 minute intervals for a
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1005 ABORT Test failed due to incompatible configuration administered in trunk group
form.
1. Verify the following fields on the trunk group administration screen:
a. Is trunk direction incoming only?
b. Is trunk outgoing type either automatic or immediate-start?
c. Is trunk the 24th port of the DS1 Interface circuit pack while
common control channel signaling is specified?
2. If the trunk has been administered using the above information, then
this test should abort.
Continued on next page